Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM03683

Parcel: 141018630


Addresses:

6074 S CEDAR ELM LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM03683

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/30/2006 FRAMING Approved IVRS - Inspection :*
01/24/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL HOLE IN 3" AB'S GARAGE
2) BANG PLATE ROMEX GARAGE
3) A.B. AT PLATE JOINT GARAGE (WEST)
4) NEED HEADER AT RANG DUCT, REPAIR IN A WORKMANSHIP MANNER
5) KITCHEN HALL WAY 12" LIGHT CAN TO PEX
01/23/2006 FRAMING Partial Approval IVRS - Inspection :*
1) STUCCO MESH NOT COMPLETE
2) FIREBLOCK TUBS
3) MESH NOT COMPLETE
4) MESH NOT COMPLETE
5) ITEM 03050 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR W. NORTH