Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM03679
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/28/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
10/27/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHIM ALL BEARING WALLS, FLR AND ROOF 2) MISSING 4' SHEAR PANEL EXTERIOR WALL 3) CLIP PARAPET TO GABLE OR NAIL WITH 8D'S 4) GAP AT LARGE SHEAR PANELS, AT BOTTOM NAIL TO BOTTOM PLATE 3" ON CENTER 16D 5) NAIL ALL 2ND FLOOR SHEAR TO FLOOR 4" ON CENTER 16D 6) NAIL FRONT PARAPET TO SHEARWALLS HORIZONTAL NAILS OR CLIP AT 24" ON CENTER |