Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM03674
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/12/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
10/11/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COLLAR TIE FRONT PORCH 2) CLIPS AND HANGER REQUIRED FRONT PORCH 3) BLOCK AND NAIL SHEATHING BREAK IN SHEAR PANELS BETWEEN TRUSSES 4) 1/8" GAP REQUIRED IN ROOF SHEATHING 5) GABLE TIES REQUIRED-BLOCKS NAILED THROUGH ROOF 6) HANGER ON BEAM OVER STAIRS 7) RELIEVE TOP PLATE AT FLOOR TRUSS BY STAIRS 8) COMPLETE RAT RUNS IN FLOOR AND ROOF |