01/19/2006 U VALUE FOR WINDOW Approved IVRS - Inspection :*
12/29/2005 U VALUE FOR WINDOW Not ready for Inspection IVRS - Inspection :*
1) MISSING WINDOWS
2) LOOSE SWITCH BOX AT KITCHEN
3) MISSING H.D. AT FRONT DOOR
4) A.B.'S AT 24" ON CENTER GARAGE
5) NEED DWV TEST
6) BANG PLATE CONDENSATE LINE LIVING ROOM TOP PLATE
7) GET INFORMATION KB11 ICBO #ER-4627
8) REDUCE BY 19 DEGREES AT 2ND FLOOR TUB ARM AND VENT NOT 6" ABOVE FIXTURE BEFORE GOING VERTICAL