Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM03666
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/04/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
11/01/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REMOVE DRY IN ROOF NAIL NOT APPROVED FROM LAST INSPECTION 2) TRUSS REPAIR NOT COMPLETE (CHECK AT NEXT INSPECTION) |
|
10/25/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FROM LAST INSPECTION, NAIL ROOF DECK 2) TRUSS REPAIRS NOT DONE, REPAIR DETAILS NOT ACCURATE AND INCOMPLETE. RE-SUBMIT FOR CLARIFICATION |
|
10/24/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FROM LAST INSPECTION: 7-NAIL TO ROOF, 3 TRUSS REPAIRS NOT DONE AND 4 CIC PLY NOT NAILED WEST AT SHINNERS-DRYED IN ALREADY |
|
10/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TWO BROKEN TRUSSES 2) NAIL OFF FLOOR 3) NAIL OFF GABLE EAST 12" ON CENTER (TOE NAIL) 4) NAIL OFF GABLE FRONT REAR 5) NAIL ALL FRIEZE BLOCKS TO ROOF 6) 3 PT BEARING SHIM 7) LARGE SHEAR PANELS NAIL OFF 4" ON CENTER NAIL TO ROOF NAIL ? PLY WEST AT SHINNERS 8) NAIL SHEAR FRONT REAR TO WALLS, TIE SHEAR TO ROOF AT FRONT ENTRY 9) FLOOR TRUSSES TURNED END TO END BEARING PT MISSION |