Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM03664
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
11/03/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) SEE LAST INSPECTION |
|
10/28/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1. TRUSS PROBLEMS 1356 MODEL NEED NEW TRUSS DRAWING 2. GUSSET PLATES MISSING AT KITCHEN CIELING 3. FRONT BEARING AT 2ND FLR GAP BETWEEN PLATE & BEAM |
|
10/26/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY, SEE LAST INSPECTION-TRUSS PROBLEM |
|
10/24/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSED NAILING ON ROOF 2) SHEAR PANELS (LARGE) NAIL AT 4" ON CENTER TOP 1 1/2" TO SHORT CAN'T NAIL TO ROOF 3) BLOCK ALL 3 PT BEARING TRUSSES 1ST AND 2ND FLOOR 4) GABLE TRUSSES NOT TIED TO TOP PLATES TOE NAIL AT 12" ON CENTER OR CLIP AT 48" 5) NAIL OFF ROOF 6) FRONT SHEAR CUT TO SHORT GAP BETWEEN BEAM AND PLATE 7) MORE NAILS IN VERTICAL 2 X 4 UNDER LIVING ROOM BEAM 8) MISSED WIND BRACE LAST 2ND FLOOR 9) RENAIL SHEAR EAST/SOUTH 10) CLIPS TRUSS TO TOP PLATES COMING OUT WEST 2ND FLOOR 11) NAIL FRONT PARAPET CLIPS 12) HEADER AT STAIR NOT 6'-8" MINIMUM |