Permit: T05CM03651

Parcel: 110073540

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
05/20/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
04/30/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- CONDENSATE TRAP NOT PER INSTALL INSTRUCTIONS
- DO NOT HAVE PVC WITHIN 6" OF VENT CONNECTOR
- PROVIDE A OVERFLOW SENSOR ON SECONDARY DRAIN
- VENT PIPE INCREASER MUST BE AT OUTLET ON FURNACE
- DO NOT USE FOIL TAPE ON VENT CONNECTORS WATER HEATER & FURNACE
- INSULATE SHEETMETAL SLEEVE/TRANSITION ON TOP OF COIL
- CONDENSATE CANNOT TERMINATE ONTO THE PORCH