Permit: T05CM03642

Parcel: 125011200


Addresses:

3033 E BROADWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/16/2005 PLUMBING - FINAL Approved PER INSP COPY
11/15/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*CANNOT USE A RUBBER FITTING ON TRAP ARM FOR THE C.O SHALL PROVIDE. APPROVED MATERIAL FOR THIS APPLICATION.
POSITION THE WYE IN A 45 DEGRE ABOVE THE TRAP ARM FOR THE C.O
11/12/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* T & P DRAIN SHALL HAVE PITCH IN MECH ROOM
PROVIDE C.O ON TRAP ARM @ LOUNGE SINK
10/19/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*SHALL PROVIDE A C.O @ SINK IN BREAK RM LOUNGE
CANNOT DISCHARGE T & P DRAIN INTO A STANDING SERVICE SINK
NOTE: OK FOT TEMP C OF O AS PER STEVE LONG