Permit: T05CM03631

Parcel: 12701005D

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T05CM03631

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/24/2005 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
07/27/2005 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK STUD FRAME WALLS
07/25/2005 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) PROTECT CABLE ABD ENT AT SHALLOW STUDS AND TOP PLATES. MOVE CABLE OUT OF SHALLOW CHANELS
2) FILL UNUSED OPENINGS
3) ABOVE CEILING VDV CABELING TO BE AS PER 725.2 AND 6, 800.2 AND 6, 760.2 AND 6
4) PLEASE VERIFY USEAGE OF ENT