Permit: T05CM03630

Parcel: 141016800

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM03630

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/31/2006 FRAMING Approved IVRS - Inspection :*
1) STILL NEED TO SEAL STUCCO OPENINGS
10/30/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED FA STRAPS KITCHEN TOP PLATE WHERE NOTCHED
2) FIRE BLOCKING KITCHEN ARCHES AND FURRED WALLS
3) FIX STUD IN BEDROOM WHERE NOTCHED MORE THAN 50 PERCENT
4) SHIM ALL WINDOW HEADERS AS NEEDED
5) BUTTERFLY REENFORCEMENT WINDOW CORNERS
6) NEED TO SEAL ALL MOISTURE BARRIERS OPENINGS
7) NEED RECEPTACLE BOXES KITCHEN COUNTER
8) RECEPTACLE ?, BEDROOM NOT NAILED TO STUD
9) BEND STAPLES AT APEX TO OUTSIDE WATER