Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/18/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/13/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 01/09/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED ELECTRIC AND PLUMBING NAIL PLATES 2) RUN GAS BOND |
|
| 12/28/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) GAS TEST OK; TEST DWV, POTABLE H20 OK 2) SHIM ALL GAPS HEADERS AT BEARING POINTS 3) MAINTAIN MINIMUM 1" CLEARANCE FLUE PIPE TO COMBUSTIBLES 4) SECURE CLOTHES WASHER BOX 5) STRAP HEADERS AT BEARING 6) GAS BOND TO BE ACCESSIBLE 7) INSTALL BANG PLATES ELECTRIC HOLES WITHIN 1 1/4" STUD FACE THROUGHOUT 8) INSTALL BANG PLATES PLUMBING HOLES WITHIN 1 1/2" STUD FACE THROUGHOUT |