Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/28/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/14/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TRUSS DRAWINGS CALL FOR 2 X STRONG BACKS BOTH ENDS OF TRUSSES
2) PLAN CALLS FOR TJI'S GARAGE (LPI'S INSTALLED)-HAVE PLAN UPDATED
11/09/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STRAP HEADERS AT BEARING
2) MASTER BEDROOM SHEARWALL WRONG LOCATION
3) SHIM TRIMMERS AT HEADERS
4) OVERSPAN STUDS TUB ENCLOSURE WALL
5) NEED APPROVED TRUSS DRAWINGS
6) NEED LADDER TO INSPECT ROOF
7) STOPPED INSPECTION
11/07/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL ITEMS NOT CORRECTED
11/03/2005 EXT METAL CLIPS/EXT SHEATHING Denied 1) MASTER BEDROOM BRACED PANEL MISSING
2) EXTERIOR CLIPS MISSING ALL EXTERIOR WALLS BOTTOM AND TOP PLATES
3) A.35 MISSING GARAGE LEDGER NORTH WAY
4) OVERSPAN SOUTH WALL AT TUB ENCLOSURE
5) ROOF PANELS MUST SPAN 2 BAYS OR 3 TRUSSES