Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM03611
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
09/23/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
09/15/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OFF SHEER TO 1 MORE STUD SE CORNER GARAGE 2) ADD BLOCKING MASTER BEDROOM FOR #3 SHEER 3) STRAP 4X12 AT FRONT WINDOW TO FRAMING 4) REMOVE SHIM BLOCKING FROM LAST 3 TRUSSES IN KITCHEN (NOT A BEARING POINT) 5) SHIM TRUSSES AT FRONT OF GARAGE (BEARING POINT) 6) STILL HAVE NOT SEEN PLOT PLAN TO CONFIRM LOCATION ON LOT |
|
09/13/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO PLANS OR PERMITS ON SITE 1) NAIL OFF SHEER PANELS THRU ROOF (NAILS MISSED) 2) REMOVE BLOCKS FROM TRUSSES WHERE NON BEARING 3) INSTALL H25S ON TRUSSES AT BEAM WHERE TRUSSES BEAR 4) ROOF NOT WALKED 5) SLUM A03 TRUSSES AT BEARING WALL |