| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/28/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*MISSING CLIPS THROUGOUT HANGER MISSING AT JACK TRUSS |
|
| 10/24/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING CLIPS THROUGHOUT 2) DBL TOP PLATE AT S.W. CORNER TO SHORT 3) CLIPS MISSING NAILS 4) NAIL PROTECT WATER LINE FROM OUTSIDE 5) SW7 CALLS FOR 5/8" A.B.'S 6) SW7 SHEAR SOUTH WEST CORNER MISSING A PIECE 7) JACK TRUSSES NOT TOE NAILED PER CALC'S |
|
| 10/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) VERTICAL STRAPS ON GARAGE HDR FOR UPLIFT 2) HANGERS ON HIP JACKS 3) NAIL GABLE DIAGONAL OUTRIGGERS THROUGH ROOF DECK 4) TIGHTEN ALL ANCHORS PRIOR TO INTERMEDIATE 5) RETRO H.D. AT BACK PATIO |
|
| 09/27/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED ON SITE BY DOUG (SUPER) |
|
| 09/26/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED ON SITE BY ROB (SUPER) OF RICHMOND AMERICAN HOMES |