Permit: T05CM03597

Parcel: 140378130


Addresses:

5893 E FANTAIL LN

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/12/2006 FRAMING Approved IVRS - Inspection :*
12/30/2005 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection
Provide 6" clearance between pex and B-vent
Provide anchor bolts at 16" on center per plan at shearwall
Bearing walls require studs at 16" on center stair
Powder room dwv out of wall
No potable water test
All items repeat
You have 5 days to pay a reinspection fee
Stopped inspection-too many items
12/27/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) PROVIDE 4-2 X 4 POSTS UNDER GLB
2) CONNECT STAIR LEDGER TO SOMETHING
3) NO DWV WATER TEST
4) PROVIDE 6" CLEARANCE BETWEEN PEX AND B-VENT
5) PROVIDE ANCHOR BOLTS PER PLAN
6) NO POTABLE WATER TEST
7) CONDENSATES NOT CONNECTED
8) POWDER ROOM DWV OUT OF WALL
9) WATER SVC STAPLED AT POWDER ROOM
10) 15 STUDS OVER NOTCHED ON NORTH WALL
11) STOPPED INSPECTION-TOO MANY ITEMS
12/21/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER TIM