Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/09/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/06/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STUD MISSING/REMOVED N.W. BEDROOM 2) 34 SHEETS OF 12' DRYWALL STACKED ON EDGER MBR N. WALL OVER LOADED FLOOR TRUSSES. PROVIDE CITY APPROVED ENGINEERING EVALUATION 3) 24 SHEETS OF 12 FT DRYWALL STACKED ON EDGE M. BR SOUTH WALL. PROVIDE CITY APPROVED ENGINEER EVALUATION |
|
| 01/05/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NO DWV WATER TEST-DO NOT COVER |
|
| 01/04/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO DWV H20 TEST 2) WHAT AIR INTAKE ? |
|
| 12/27/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO CHANGE FROM LAST INSPECTION |
|
| 12/21/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO INSULATE 2) NO SECOND FLOOR DWV TEST 3) 10 FEET REQUIRED BETWEEN DWV VENT AND AIR INTAKE |