Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03584

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/01/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/25/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TRUSS DRAWINGS SHOW AVB & AV TRUSS WITH RAT RUNS, THERE ARE 10 EACH. TRUSS DRAWINGS SHOW QUANTITY AS 1 EACH ?
2) NAIL BOTTOM PLATES 6" ON CENTER AT SHEARWALLS 2ND FLOOR
3) MISSING SIX NSTC48 STRAPS
4) SHEAR BLKS BETWEEN RAFTER TAILS AT BEARING AREN'T HIGH ENOUGH