Permit: T05CM03578

Parcel: 116124670


Addresses:

1455 W SONORA ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/03/2006 FRAMING Approved IVRS - Inspection :*
11/01/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPLACE CUT STUD IN KITCHEN
2) PROPERLY VENT ROOF
10/26/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PANCAKE AT BACK PATIO MUST BE GROUNDED
2) WIRE BOX AT BACK OF HOUSE
3) VACUUM BREAKER REQUIRED ON HOSE BIB
4) SUBMIT LIGHTING SCHEDULE FOR APPROVAL OF EXTERIOR LIGHTS
5) BLOCK STUD BAYS FOR RETURN AIR
6) TERMINATE WIRE IN CLOSET IN APPROVED OUTLET BOX
7) FILL DWV
8) EAVE VENTS NOT PER PLAN
9) INSTALL FASCIA AND BARGE RAFTERS
10) REPLACE CUT STUD AT KITCHEN HOOD VENT
11) STOPPED INSPECTION
10/13/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MUST HAVE ATTIC ACCESS
2) BLOCK TOP AND BOTTOM COMUSTION VENTS GARAGE
3) INSTALL H20 HEATER PTR LINE TO EXTERIOR
4) WINDOWS NOT PER PLAN
5) FURNACE LOCATION NOT PER PLAN
6) INSTALL ROOF JACKS ALL PENETRATIONS
7) MUST INSTALL PLATFORM FOR H20 HEATER
8) WASHER BOX TO HIGH
9) GAS TEST TOO LOW
10) BLOCK 3 SIDES MECH VENTS CEILING
11) NO TEST DWV
12) INTERIOR WALL OMITTED BETWEEN LIVING AND DINING ROOM
13) STOPPED INSPECTION-AS BUILTS FOR APPROVAL