Permit: T05CM03554

Parcel: 140376550


Addresses:

6845 S HARRIER LP

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/08/2005 FRAMING Approved IVRS - Inspection :*
12/06/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) SECURE STAIR PONY WALL
2) RED HEAD ANCHOR BOLTS LOOSE
3) A/C COPPER OUT OF WALL
4) BLOCK DUCT BOOTS 3 SIDES POWDER ROOM
5) DWV HORIZONTAL RUN REQUIRES 1/4"/FT PITCH
6) GAS LEAK LOST 1/2 POUND IN 10 MINUTES
7) STOPPED INSPECTION-NEXT FAILURE WILL REFEE
12/05/2005 FRAMING Cancelled CANCELLED PER TIM OF K.B. HOMES #907-6040
11/28/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) NO DWV WATER TEST
2) NO GAS PRESSURE TEST
3) RED HEAD ANCHOR BOLTS LOOSE
4) STAIR RISERS CANNOT EXCEED 7 3/4" PRESENTLY 8"
5) HOUSE NOT READY
6) STOPPED INSPECTION
7) SUPERINTENDENT TO INSURE WORK IS COMPLETE PER PLAN AND CODE PRIOR TO CALLING FOR INSPECTION