Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: STEM WALL/RETAINING WALL
Permit Number - T05CM03548
Inspection Description - STEM WALL/RETAINING WALL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2006 | STEM WALL/RETAINING WALL | Approved | IVRS - Inspection :* | |
05/05/2006 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* TOP OUT MASONRY |
|
05/02/2006 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
03/14/2006 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* ALL PANELS EXCEPT 20 & 21 |
|
03/10/2006 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* PANELS 8-12 OK TO PLACE - FINISH CUTTING STEEL FOR CLEARANCE @ JAMBS |
|
03/03/2006 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* TILT PANELS 17-18-19, 28, 29, 30 OK PER PLAN PLEASE CONSULT WITH ENGINEER ABOUT SPLICES OF #8 STEEL (36" EMBED PER SHOP DRAWING) ALONG SLAB LINE. |
|
02/28/2006 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*T.IT PANELS 22,23,24 OK TO PLACE PANEL 25,26 OK WHEN SPECIAL INSPECTOR CONFIRMS FINAL MINOR STEEL PLACEMENT. | |
02/24/2006 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*TILT PANELS 7,6,5,4,3,1 |