Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/01/2006 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 11/28/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*TOP OUT SOUTH TOWER | |
| 11/23/2005 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 11/22/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*SOUTH TOWER TO 72' OK TO GROUT WHEN SPECIAL INSP., CONFIRMS FINAL VERTICAL IN PLACE | |
| 11/21/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*SOUTH TOWER OK TO 68' | |
| 11/18/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH TOWER @ 60' SOUTH TOWER OK TO 64' HIGH |
|
| 11/17/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 11/16/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*SOUTH TOWER OK TO 56' | |
| 11/15/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*TOP OUT N. TOWER OK, 52' SOUTH TOWER OK | |
| 11/10/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) NORTH TOWER OK TO 56' WHEN SPECIAL INSPECTION CONFIRMS |
|
| 11/09/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 52' NORTH STAIR. 48' SOUTH STAIR | |
| 11/07/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 44' BOTH STAIR WELLS |
|
| 11/04/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*STAIR B (36'-40' AFFE) | |
| 11/03/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*36'SOUTH STAIR WELL STAIR A ( 36'-40'ASF?) STAIR B ( 321-36' A???) |
|
| 11/02/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 11/01/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*32' BOTH STAIR/ ELEV SHAFTS | |
| 10/31/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*28' AT BOTH STAIR /ELEV WHEN SP INSP CONFIRMS FINAL VERTICALS ( H?? & BE?? SEAT OK) | |
| 10/28/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*24' ELEV SHAFTS | |
| 10/27/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*20' AFF OK BATH STAIR/ELEV ??? | |
| 10/25/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*12' AFF OK TO GROUT ( BOTH ELEV/STAIR SHAFTS) | |
| 10/24/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*20' 3/0 BARE ?? WIRE INSTALLED AND CLAMPED TO REBAR. | |
| 10/20/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*OK TO GROUT 4' AFF FOR AREA 0-1/BC WHEN SPECIAL INSPECTOR CONFIRMS FINAL VERTICAL PLACEMENT. | |
| 10/18/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*OK TO GROUT TO STEM HEIGHT 0-1/B-C. OK TO USE BLOCK AS FORM AND THEN FILL FOR CIP STEM ON LINE B | |
| 10/17/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*4'' STAIR WALLS AREA 3-B |