Permit: T05CM03547

Parcel: 12810079C

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T05CM03547

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
06/01/2006 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
11/28/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*TOP OUT SOUTH TOWER
11/23/2005 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
11/22/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*SOUTH TOWER TO 72' OK TO GROUT WHEN SPECIAL INSP., CONFIRMS FINAL VERTICAL IN PLACE
11/21/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*SOUTH TOWER OK TO 68'
11/18/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* SOUTH TOWER @ 60'
SOUTH TOWER OK TO 64' HIGH
11/17/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
11/16/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*SOUTH TOWER OK TO 56'
11/15/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*TOP OUT N. TOWER OK, 52' SOUTH TOWER OK
11/10/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) NORTH TOWER OK TO 56' WHEN SPECIAL INSPECTION CONFIRMS
11/09/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* 52' NORTH STAIR. 48' SOUTH STAIR
11/07/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 44' BOTH STAIR WELLS
11/04/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*STAIR B (36'-40' AFFE)
11/03/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*36'SOUTH STAIR WELL
STAIR A ( 36'-40'ASF?) STAIR B ( 321-36' A???)
11/02/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
11/01/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*32' BOTH STAIR/ ELEV SHAFTS
10/31/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*28' AT BOTH STAIR /ELEV WHEN SP INSP CONFIRMS FINAL VERTICALS ( H?? & BE?? SEAT OK)
10/28/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*24' ELEV SHAFTS
10/27/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*20' AFF OK BATH STAIR/ELEV ???
10/25/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*12' AFF OK TO GROUT ( BOTH ELEV/STAIR SHAFTS)
10/24/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*20' 3/0 BARE ?? WIRE INSTALLED AND CLAMPED TO REBAR.
10/20/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*OK TO GROUT 4' AFF FOR AREA 0-1/BC WHEN SPECIAL INSPECTOR CONFIRMS FINAL VERTICAL PLACEMENT.
10/18/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*OK TO GROUT TO STEM HEIGHT 0-1/B-C. OK TO USE BLOCK AS FORM AND THEN FILL FOR CIP STEM ON LINE B
10/17/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*4'' STAIR WALLS AREA 3-B