Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM03542

Parcel: 141018410


Addresses:

6051 S CEDAR ELM LN


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03542

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/14/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/06/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BROKEN TRUSS
2) MISSED NAILS ON ROOF
3) CUT 6" RIPPER OUT 79C INSTALL 2'-0" PANEL, RENAIL PANELS
4) NAIL OFF FLOOR
5) SHIM 3 PT BEARING
6) 1ST AND 2ND FLOOR STRAPS NOT NAILED MISSING STRAPS AT FRONT 1ST/2ND FLOOR
7) ROOF NAILING STAPLES 3"=6" ON CENTER EDGE/FIELD
8) 4'-0" SHEAR PANEL EAST WALL