Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/19/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/18/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRONT PARAPET ADD TO VERT 2 X 4'S 2) NAIL FLOOR 3) SHEIM ALL 3 PT BEARING 4) NAIL OFF ALL MAS 5) MISSING HANGER NAILS FRONT PORCH 6) GABLE TRUSS TO DBL TOP PLATE WEST 7) FRONT SHEAR AT GARAGE FIX AT BOTTOM PLATE 8) NAIL HORIZONTAL JOINTS EACH SIDE |