Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2005 | FRAMING | Approved | IVRS - Inspection :* 1) INSTALL ALL BLOCKS AT 1ST FLOOR SHEAR THAT ARE TO HIGH OR HAVE BEEN KNOCKED OUT OF PLACE 2) SEE LAST INSPECTION |
|
| 12/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIX ALL PEX LINES TO CLOSE TO LIGHT CANS 2) BANG PLATE 2" ABS AT GARAGE 3) NEED DWV TEST 4) NEED POTABLE H20 TEST 5) STAIR RAIL WALL LOOSE 6) FHA STRAP ACROSS NOTCH DBL TOP PLATE 2ND FLOOR WEST BEDROOM 7) BANG PLATE SOLAR CU. LINES 8) BLOCK TUB SIDES 9) NAIL 2ND FLOOR SHEARWALLS TO FLOOR 4" ON CENTER 10D'S 10) OVERSPAN AT FRONT DOOR 11) ROMEX CONNECTORS AT CAN LIGHTS |