Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/28/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/26/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ROOF DRY-IN/ALREADY DONE |
|
| 09/29/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING ROOF NAILING 2) SHEAR PANEL BLOCKS NAIL TO ROOF, NAIL SHEAR PANELS 4" ON CENTER ALSO SHEAR WALL BELOW 3) FRONT SHEAR NAIL ALL PERIMETERS 4) BLOCK OSB TURNED WRONG WAY FRONT OVER FRAME 5) TIE ALL GABLE CORDS TO PLATES AT SIDES AND FRONT 6) X BRACE NOT NAILED 7) FLOOR DECK NOT SCREWED 8) MISSING WIND BRACE 2ND FLOOR WEST 9) SHEAR PANEL MISSING WEST FRONT GARAGE 10) STRAP WALLS TO BEAMS FRONT BACK 48" ON CENTER |