Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM03534

Parcel: 141018160


Addresses:

6031 S CEDAR ELM LN


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03534

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/28/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/26/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ROOF DRY-IN/ALREADY DONE
09/29/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING ROOF NAILING
2) SHEAR PANEL BLOCKS NAIL TO ROOF, NAIL SHEAR PANELS 4" ON CENTER ALSO SHEAR WALL BELOW
3) FRONT SHEAR NAIL ALL PERIMETERS
4) BLOCK OSB TURNED WRONG WAY FRONT OVER FRAME
5) TIE ALL GABLE CORDS TO PLATES AT SIDES AND FRONT
6) X BRACE NOT NAILED
7) FLOOR DECK NOT SCREWED
8) MISSING WIND BRACE 2ND FLOOR WEST
9) SHEAR PANEL MISSING WEST FRONT GARAGE
10) STRAP WALLS TO BEAMS FRONT BACK 48" ON CENTER