Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM03529

Parcel: 141018110


Addresses:

6014 S CEDAR ELM LN


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03529

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/14/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/03/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) TRUSS REPAIR DOESN'T ADDRESS DAMAGE AT GUSSET PLATE CONNECTION TO BOTTOM CHORD
10/24/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection 1) FROM LAST INSPECTION 2 AND 4 NOT DONE
10/18/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 4" ON CENTER LARGE PANELS, NAIL TO ROOF
2) FIX TRUSS 79C1
3) ATTACH 1ST AND 2ND FLOOR GARAGE SO. AT BEAM
4) SHIM 3 PT BEARING
10/05/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) CLIP FRONT POP OUT TRUSS TO WALL BELOW
2) SHEAR TRANSFER AT FRONT ENTRY
3) BROKEN TRUSS ROOF SOUTH
4) SHEAR PANELS LARGE TO ROOF INSTALL TOP PLATE NAIL 4" ON CENTER PLY WOOD TO BOX MEMBER, THEN NAIL 4" ON CENTER TO ROOF
5) NAIL FRIEZE BLKS TO ROOF FRONT AND REAR
6) SHIM 3PT BEARING
09/27/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEAR PANELS HAVE NO TOP PLATES
2) FRONT AND REAR BEARING WALLS NOT ITED TO BEAMS
3) FINISH ALL SHEAR AND SHEAR TRANSFERS
4) SCREW FLOOR DECK, NOT SECURED
5) BROKEN TRUSS
6) NAIL GABLE BOTTOM CHORDS TO TOP PLATES
09/20/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) WALK HOUSES BEFORE CALLING IN