Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/31/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 01/27/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920*ALL DOORS ARE LOCKED NO ONE ON SITE NO MESSAGE |
|
| 01/26/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SOUTH UNIT 1. NEED GFI PROTECTION FOR COUNTER OUTLET NEXT TO FRIDGE. 2. DISPOSAL OUTLET NOT WIRED AND NEEDS BOX EXTENDER 3. NEED BUSHING OR CONNECTOR FOR HOOD FAN WIRE 4. INSTALL OUTLET COVER @ ENTRY 5. SHOULD HAVE RECEPT, WITHIN 6' OF EACH SIDE OF DOOR IN KIDS BEDROOM 6. SHOULD HAVE OUTLET IN HALLWAY 7. PANEL IS NOT CORRECTLY MARKED 8. GROUND ALL SWITCHES NORTH UNIT: 1. NEED GFI NEXT TO FRIDGE IN KITCHEN 2. NEED RECEPT IN KIDS BED 3. NEED RECEPT IN HALL 4. GROUND SWITCHES 5. DISPOSAL OUTLET NOT WIRED NEEDS EXTENDER 6. BUSHING FOR HOOD 7. BOTH PANELS NEED TO BE CORRECTLY AND LEDGIBLY MARKED - NEED NEW LABELS. |
|
| 01/24/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT 2 INSPECTED AT THIS TIME ONLY 1. ALL KITCHEN COUNTER OUTLETS NEED GFI PROTECTION 2. WEST BEDROOM MISSING OUTLET BY DOOR/CKT IS DEAD TO LIGHT? 3. BATHROOM GFI OUTLETS NOT WORKING 4. EAST BEDROOM OUTLET HAS REVERSED POLARITY 5. DISPOSAL OUTLET NOT INSTALLED 6. PANEL DIRECTORY NOT CORRECTLY MARKED 7. EXTERIOR OUTLETS NEED GFI PROTECTION (NOT DRYER) 8. NEED LIGHT AT WATER HEATER CLOSET 9. GO THROUGH UNIT ONE FOR THESE SAME CORRECTIONS. |
|
| 11/18/2005 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK TO CLEAR ECO 1 & 2 1) STRAP GROUND WIRE TO WALL OUTSIDE INSIDE BREAKER PANEL WILL NEED TO FACE OUTSIDE CLOSET TO COMPLY WITH CODE. SEE METER LAST INSPECTION-READ CODE ARTICLE |
|
| 10/12/2005 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* INSTALL BRACES FOR AC DISCONNECTS ON ROOF PANELS CANNOT BE INSTALLED IN CLOSETS UNLESS 240-24 D DOOR FACING OUT |