Permit: T05CM03514

Parcel: 116121320

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
01/31/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
01/27/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*ALL DOORS ARE LOCKED NO ONE ON SITE NO MESSAGE
01/26/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SOUTH UNIT
1. NEED GFI PROTECTION FOR COUNTER OUTLET NEXT TO FRIDGE.
2. DISPOSAL OUTLET NOT WIRED AND NEEDS BOX EXTENDER
3. NEED BUSHING OR CONNECTOR FOR HOOD FAN WIRE
4. INSTALL OUTLET COVER @ ENTRY
5. SHOULD HAVE RECEPT, WITHIN 6' OF EACH SIDE OF DOOR IN KIDS BEDROOM
6. SHOULD HAVE OUTLET IN HALLWAY
7. PANEL IS NOT CORRECTLY MARKED
8. GROUND ALL SWITCHES
NORTH UNIT:
1. NEED GFI NEXT TO FRIDGE IN KITCHEN
2. NEED RECEPT IN KIDS BED
3. NEED RECEPT IN HALL
4. GROUND SWITCHES
5. DISPOSAL OUTLET NOT WIRED NEEDS EXTENDER
6. BUSHING FOR HOOD
7. BOTH PANELS NEED TO BE CORRECTLY AND LEDGIBLY MARKED - NEED NEW LABELS.
01/24/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
UNIT 2 INSPECTED AT THIS TIME ONLY
1. ALL KITCHEN COUNTER OUTLETS NEED GFI PROTECTION
2. WEST BEDROOM MISSING OUTLET BY DOOR/CKT IS DEAD TO LIGHT?
3. BATHROOM GFI OUTLETS NOT WORKING
4. EAST BEDROOM OUTLET HAS REVERSED POLARITY
5. DISPOSAL OUTLET NOT INSTALLED
6. PANEL DIRECTORY NOT CORRECTLY MARKED
7. EXTERIOR OUTLETS NEED GFI PROTECTION (NOT DRYER)
8. NEED LIGHT AT WATER HEATER CLOSET
9. GO THROUGH UNIT ONE FOR THESE SAME CORRECTIONS.
11/18/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :* OK TO CLEAR ECO 1 & 2
1) STRAP GROUND WIRE TO WALL OUTSIDE
INSIDE BREAKER PANEL WILL NEED TO FACE OUTSIDE CLOSET TO COMPLY WITH CODE. SEE METER LAST INSPECTION-READ CODE ARTICLE
10/12/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :* INSTALL BRACES FOR AC DISCONNECTS ON ROOF
PANELS CANNOT BE INSTALLED IN CLOSETS UNLESS 240-24 D DOOR FACING OUT