Permit: T05CM03502

Parcel: 118082140


Addresses:

986 W CALLE CARASOL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/03/2006 FRAMING Approved IVRS - Inspection :*
05/02/2006 FRAMING Denied 1) FIRE STOP N.W. CHASE
2) FIRE BLOCK IN KITCHEN
3) FIRE STOP SUPPLY DUCT 2ND FLOOR
04/27/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OVER BOARD FRAMING ON PLUMBING TO BE ADDRESSED
2) INSTALL BANG PLATES ON PLUMBING THROUGHOUT
3) DWV TEST TO GO THRU ROOF
4) PORCH LEDGER TO HAVE POSITIVE ATTACHMENT TO HEADER
5) STOPPED INSPECTION