Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03488

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/24/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/18/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2 NAILS REQUIRED AT BOTTOM PLATE OF WIND BRACES
2) TIE DBL 2 X12 TO POST IN GARAGE
3) STRAP TOP PLATE BREAK
4) TIE TOP PLATE TO STUDS AT ELEVATION CHANGES
5) NAIL LEDGERS TO BLOCKS