Date Description Inspector Results Comments
03/01/2006 FRAMING Approved IVRS - Inspection :*
02/27/2006 FRAMING Partial Approval IVRS - Inspection :*
1) SHIM 3 PT TRUSS AT GARAGE TO KITCHEN
2) 2 A.B. NEED AT STAIR SHEAR
3) GARAGE WALL AT H2.0 HTR AREA, WALL CROOKED
4) HOLE IN FLOOR 2ND FLOOR A/C LINE SET
5) ITEM 03050 NOT REQUIRED-ALL ELECTRIC