Inspection History: ELECTRIC - FINAL
Permit Number - T05CM03427
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/29/2005 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
12/28/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEUTRAL AND GROUND WIRES DAMAGED BY OVER TORQUING-REPAIR ALL WIRES AND TORQUE TO LABEL SPECIFICATION 2) ALUMINIUM CONDUCTORS REQUIRES ANTI-CORROSION COMPOUND 3) FURNACE DISCONNECT MISSING COVER 4) M/WC REQUIRES 15" TO CABINET |