Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM03403

Parcel: 111083740

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T05CM03403

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/18/2005 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
08/04/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOT READY
1. TRIM OUT SW BOX BY FRONT DOOR.
2. GROUND CEILING BOX LIV. RM.
3. METAL STUD WALLS USE PLASTIC GROMETS ON ROMEX & TIE ALL ROMEX.
4. FINISH AC & KIT. WALL
5. STRAP PNL FEEDER
6. STRAP WIRING ABOVE PNL
7. GRD ALL METER BOXES