Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/13/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/11/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED 2" VENT AT 2ND FLOOR TOILET 2) ROMEX NOT CONNECTED ENTRY LIGHT, ROLLED UP ROMEX FIT LID 3) RECEPTACLE NOT WIRED LIVING ROOM 4) WRONG SIZE HANGER 5) NEED HUS 410 HANGER AT ROOF GIRDER 6) LARGE GIRDER IS 3 PT BEARING, ADD DBL 2 X DOWN TO FLOOR 7) BLOCK FLOOR OSB AT JOINT WEST BEDROOM 8) BATHROOM ABOVE KITCHEN NOT PLUMBED CORRECTLY 9) FURNACE FLUE NOT SNAPPED TOGETHER AT JOINT 2ND FLOOR CLOSET, CEILING 10) NEED H20 POTABLE TEST 11) MISSING BANG PLATES THRU-OUT SEE GARAGE SIDE OF T3P CONDENSATE 12) NEED DWV TEST 13) POSITIVE PITCH LAUNDRY VENT 14) SECURE SWITCH 2ND FLOOR BATH 15) LOWER FIRE STOP GARAGE DROP |