Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM03365
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) NOTE: FLOOR DECK NOT NAILED (CAN USE 10D'S AT 6"-10" OR SCREW AT 6" |
|
11/29/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE NAILING OFF HIP HANGERS THRU OUT 2) NEED BOLTS IN INTERIOR HOLDOWNS 3) ROOF OK TO DRY IN 4) FLOOR NOT SCREWED DOWN 5) STRAP OFF MICRO LAM TOP OF STAIRS 6) NEED 2 H2.5'S AT GIRDER TRUSSES 7) EXTEND HEADER OVER FRONT DOOR TO WEST 8) CHANGE SHEAR #8 TO 1/2" OR ADD 3/8 TO INSIDE |