Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM03360
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
12/30/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* | |
12/27/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RAT RUNS ALL NEED D-4, D-5, D-6A-3 PT-TOTALS 5, D-6B-3 PT-TOTAL 2 2) FINISH SHEAR 3) INSTALL TBEC HARDWARE EACH SIDE OF 3 PT TRUSSES 4) CONNECT SHEAR TO ROOF PER PLAN 5) FINISH WIND BRACE WEST SIDE 6) BLOCK AND NAIL OSB JOINT HIP ROOF 7) INSTALL MSTC 40 AT EAST WALL 8) 1ST AND 2ND FLOOR STRAPS TO BE C.S. X16 X 48" AT 48" ON CENTER |
|
12/19/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) INSTALL RAT RUNS 2) Q10 TRUSSES ARE 3 PT BEARING 3) Q10B TRUSSES ARE 3 PT BEARING 4) FINISH SHEAR 5) FINISH WIND/BRACES 6) NAIL OFF FLOOR 7) MISSING BLOCK AND NAILS AT REAR OSB JOINT, OSB TURNED PARALLEL TO TRUSSES 8) HANGERS MISSING NAILS 9) 2 STUDS UNDER GIRDERS ALL THE WAY DOWN TO CONCRETE (BETWEEN FLOORS) |