Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03358

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/25/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) CHECK HEIGHT OF DIRECT VENT CHIMNEY
04/21/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) SEE LAST INSPECTION
04/18/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) 1ST/2ND FLOOR STRAPS 48" ON CENTER
2) FRONT DOOR TRIMMER 1/2" PLY
3) NAIL AND OR BLOCK HORIZONTAL JOINTS EXT. SHEAR
4) BRING ALL BEARING PT. LOADS DOWN TO CONC SLAB
5) SHIM 3PT BEARING TRUSSES
6) 10/DT1 BEAM HANGER PLAN CALLS FOR HUS 410 SIMPSON ADVANCED INSTALLED CHECK EQUAL
7) NAIL DOWN ALL EXT. & SHEAR WALL PLATES PER PLAN
8) INSTALL MSTC STRAPS 2ND FLOOR A TOTAL
9) TWO GIRDER TRUSSES ROOF ARE NOT 3 PT BEARING NOTCH UNDER DBL STUD AT PALTES FOR DEFLECTION