Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/21/2006 FRAMING Approved IVRS - Inspection :*
02/17/2006 FRAMING Partial Approval IVRS - Inspection :*
1) BLOCK ALL MECH DUCTS
2) RETRO H.D. REAR WALL
3) FLUE FIRE STOPS
4) REAR NOT DONE
5) NEED MTT28B AT INTERIOR SHEAR NAIL OSB TO DBL STUD
6) OK TO INSULATE