Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM03355
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
12/27/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO DRY IN ROOF AND WALLS 2) SEE LAST INSPECTION |
|
12/20/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED CONCRETE CORRECTIONS MADE AND FINAL PORCH FRAMING 2) NEED HOLDOWNS AS PREVIOUSLY NOTED |
|
12/15/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXTEND SHEAR NORTH WEST CORNER TO CONNECT WALLS TOGETHER 2) NAIL ROOF TO TRUSS WITH 8D NAILS OVER SHEAR WALL 3) ADD H.D. NORTH WALL AND GARAGE WALL WHERE MARKED 4) PORCH NOT COMPLETED PENDING CONCRETE REPAIR 5) TRANSFER SHEAR FROM WALL TO TRUSS PER D1-21 6) ADD MST 38 STRAPS PER PLAN NORTHWEST CORNER |