Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/31/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NAIL ALL SHEAR AT HORZ JOINTS 2) MISSING TOTAL OF 5 MSTC28 STRAPS 3) TIE TOP OF SHEAR TO TRUSS BOTTOM CHORD 4) REAR COLS. NOT TIED TO B/PLATES 5) FRONT AND REAR GABLE TRUSSES, REQ. FULL BEARING AT JOINTS SPECIFIED ON SHOP DRAWINGS 6) 2 NAILS IN EACH END OF WIND BRACE AT BOTTOM PLATES |