11/07/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) CHECK RETRO H.D.'S AT INTERMEDIATE |
|
11/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OFF LARGE SHEAR BLK PANELS 4" ON CENTER 2) SHIM ALL 3 PT BEARING 3) MISSING DIAGONAL BRACING BOTH SIDES 4) MISSING RAT RUNS 5) NEED A.35'S AT FRONT FRIEZE BLKS 6) NAIL ALL CSS STRAPS AT FRONT BEAM 7) NEED STRUCTUAL STRAPS AT EACH SIDE OF GARAGE 8) TIE EACH END OF NORTH GABLE TO TOP PLACE 9) PULL CABLES 10) GARAGE RETRO H.D.'S 11) NO PANEL INSTALLED |