Permit: T05CM03344

Parcel: 141017830

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03344

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/07/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) CHECK RETRO H.D.'S AT INTERMEDIATE
11/02/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL OFF LARGE SHEAR BLK PANELS 4" ON CENTER
2) SHIM ALL 3 PT BEARING
3) MISSING DIAGONAL BRACING BOTH SIDES
4) MISSING RAT RUNS
5) NEED A.35'S AT FRONT FRIEZE BLKS
6) NAIL ALL CSS STRAPS AT FRONT BEAM
7) NEED STRUCTUAL STRAPS AT EACH SIDE OF GARAGE
8) TIE EACH END OF NORTH GABLE TO TOP PLACE
9) PULL CABLES
10) GARAGE RETRO H.D.'S
11) NO PANEL INSTALLED