Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) STUDS ON BEARING WALL REQUIRED AT 16" ON CENTER OVERSPAN 2) N.E. CORNER MISSING CLIPS 3) MISSING NAILS-FILL ALL HOLES IN RSP4 CLIPS 4) HEADERS MUST BEAR ON TRIMMERS 5) CLIP POSTS FOR GIRDERS 6) STOPPED INSPECTION-TO MANY ITEMS |