Permit: T05CM03325

Parcel: 140378120


Addresses:

5887 E FANTAIL LN

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/21/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/20/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ROOF SHEATHING NOT NAILED TO GOOD-PORCH RAFTERS
12/15/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER TIM
12/12/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 6 EACH RAFTERS TO SHORT TO SIT IN HANGERS
2) MISSING H2.5 3 RAFTERS
12/06/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) PENDING BACK PATIO
11/29/2005 EXT METAL CLIPS/EXT SHEATHING Denied 1) PORCH NOT BUILT
2) REAR P-1 MISSING
3) SOUTH EAST HOLDOWN MISSING
4) OSB ROOF SHEATHING MUST SPAN 2 BAYS-3 TRUSSES
5) REPLACE 14 PANELS
11/23/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLIP SOUTH END OF GARAGE HDR
2) COMPLETE SHEAR NAILING SOUTH SIDE
3) 2 NAILS REQUIRED AT TOP AND BOTTOM PLATES OF ALL WIND BRACES
4) RETRO H.D. ON SOUTH WALL
5) H2.5 AT ENTRY
6) STRAP HDR AT STAIRS DOWN
7) STRAP BREAK IN TOP PLATES AT PANTRY
8) NAIL STRAP TO GABLE ON NORTH SIDE
9) STOPPED INSPECTION-TOO MANY ITEMS