Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/28/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NO SECOND FLOOR DWV WATER TEST 2) OK TO INSULATE |
|
| 12/27/2005 | FRAMING | Cancelled | CANCELLED PER SUPERINTENDENT JOE OF K.B. HOMES #907-6049 | |
| 12/20/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RED HEAD ANCHOR BOLTS LOOSE 2) TWO NOTE C SHEAR ANCHOR BOLTS NOT INSTALLED 3) POWDER ROOM LIGHT NOT FLUSH 4) STAIRS CANNOT EXCEED 7 3/4" RISE 5) NO SECOND FLOOR DWV WATER TEST 6) SEWER DWV VENT CANNOT BE WITHIN 10 FEET OF MECHANICAL AIR INTAKE 7) WIRES BELOW CEILING 8) SUPPORT CONDENSATE AT 4' ON CENTER 9) W/H VENT REQUIRES 1" TO WOOD |
|
| 12/14/2005 | FRAMING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925* 1) POST TENSION CABLES NOT TENSIONED 2) ROOF LOADED 3) REPAIR STUCCO PENETRATIONS 4) NO PLANS OR PERMIT ON SITE |