Permit: T05CM03324

Parcel: 140378380


Addresses:

6768 S AQUILINE DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/14/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/08/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REAR WALL NOT BEARING ON RIM JOIST
2) REMOVE RIBBON-SEE ITEM 3 OF 11/04/05 INSPECTION
11/04/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GABLE END TRUSSES NOT CLIPPED ON END PER 1/SD3
2) S.W. CORNER NOT CLIPPED AT SILL PLATE
3) SECOND FLOOR SILL PLATE NOT BEARING ON STRUCTURE AT N.W. CORNER-REMOVE RIBBON ON WEST WALL FOR SILL PLATE INSPECTION
4) RIBBON OSB NORTH WALL NOT NAILED PER 1/SD2
5) NORTH P-1 NOT PER PLAN
6) OSB ROOF PANELS MUST SPAN 3 TRUSSES OR TWO BAYS
7) ENTRY COLUMNS REQUIRE TWO ANCHOR BOLTS PER SILL PLATE