Permit: T05CM03317

Parcel: 124041020

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05CM03317

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/09/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
07/11/2006 PLUMBING - FINAL Not ready for Inspection - NO SHOCKABSORBERS
- NO INSULATION ON HOT & COLD SUPPLY AT WATER HEATER
- TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEGREES W/O ADDITIONAL CLEANOUT.
- SHAMPOO BOWL CLEANOUTS CONCEALED BEHIND WALL
- INSTALL CO TAPPED PLUG W/MACHINE SCREW AND COVER AT WH.
07/07/2006 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
NO PROBLEMS EXCEPT CANNOT FINAL THIS PERMIT, SHELL BUILDING DOES NOT HAVE FINAL APPROVAL.