| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/22/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) PROVIDE H2.5 BOTH SIDE BEAM CARPORT AND ADDITION REQUIRED AT FRAMING INSPECTION 2) TO BE COMPLETED WHEN ALL INTERMEDIATES COMPLETE |
|
| 11/18/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) SHEATHING OK 2) INSPECTION TO BE DONE WHEN INTERMEDIATES READY 3) ALL 2 X 4 BARE PLATES MUST BE PRESUURE TREATED MATERIAL 4) PROVIDE STRAPS OR CLIPS H2.5 FOR 6 X 10 BEAM ON TOP AND BOTTOM EAST END AND ADD 2 X 6 ON WEST END SUPPORT CEILING H2.5'S TOP AND BOTTOM 5) ROOF NAIL SOUTH END NOT COMPLETE ADDITION OK 6) CARPORT NOT READY 7) PROVIDE CLIPS ON SOUTH 2 X 8 RAFTER TO BEAM CONNECTION |