Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/15/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 3/8" OSB SHEATHING MUST BE INSTALLED WI9TH LONG DIMENSION PER PENDICTULAR TO STUDS PER S-1 ROUGH CARPENTRY NOTE 3 AND IRC R602.10.3 SUB PARAGRAPH 3 AND TABLE 602.3(3) NOTE B 1/2" MAYBE INSTALLED VERTICALLY 2) ROOF SHEATHING NOT NAILED IN SEVERAL LOCATION 3) OSB ROOF SHEATHING MUST BE INSTALLED WITH LONG DIMENSION PERPENDICULAR TO TRUSSES 4) PROVIDE CITY APPROVED PLANS WITH TD NUMBER 15-77-16 5) PROVIDE PLYWOOD CLIPS PER NOTE 3 |