Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM03212

Parcel: 133191020


Addresses:

6781 E BAKER ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/07/2006 FRAMING Approved IVRS - Inspection :*
02/17/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOT BUILT TO PLAN
2) ALL LUMBER AT CONCRETE MUST BE TREATED
3) HEADER OVER KNOTCHED 4 X 8
4) 4 X 6 POSTS MAY NOT BE ON CONCRETE-SEE CROSS SECTION
5) INSTALL HOLDOWNS
6) INSTALL EXTERIOR BOX AND SWITCH AT SLIDER
7) STOPPED INSPECTION