Permit: T05CM03208

Parcel: 118082310

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03208

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/07/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/29/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SW2 NAILING 4"-12" PATTERN
2) SW PLATE BOLTS NOT PER PLAN
3) INSTALL BANG PLATES EXTERIOR BOTTOM PLATES AT PLUMBING CUTS
4) INSTALL PLUMBING VENT PIPE BACK BACK INTO WALL
5) HOLDOWN LOCATIONS TO BE AT EACH END OF SHEAR PANELS
6) STAPLES TO BE SET FLUSH WITH ROOF SHEATHING
7) STOPPED INSPECTION