Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM03177

Parcel: 13821019E


Addresses:

113 W CORONA RD #01

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
02/28/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
01/31/2008 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/30/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
ABS UNDERGROUND PIPING W/WATER TEST ONE RISE OK
OK TO COVER
CONTRACTOR RESPONSIBLE FOR PROVIDING CLEAN FILL
RECALL FOR INSPECTION PRIOR TO CONCRETE
01/27/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
COUPLING ON WC STUB IS LEAKING
PLUMBING SPEC 3B CALLS FOR A 24HR WATER TEST ON WASTE PIPING
1. CORRECT LEAK, TEST 24 HRS PRIOR TO INSPECTION
2. REMOVE ROCKS & CHUNKS LARGER THAN 3/4" FROM PIPING
3. SUPPORT TRAP ARM AT TUB - CONTRACTOR TO PROVIDE FILL MATERIAL OF 3/4 MINUS
TRACER WIRE REQUIRED ON ALL EXTERIOR PIPING
ADDRESS NOT VISIBLE WITH GATE OPEN
01/26/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
WATER TEST DOWN, POSSIBLE LEAK AT CLOSET
PLEASE REDLINE CHANGE OF LOCATION OF WASHER AND KIT DRAIN LINES